Refrigerant Accumulators

In an air conditioning system, before the refrigerant returns to the compressor, it must be ensured that the refrigerant is completely vaporized. Therefore, gas and liquid must be separated before entering the compressor, allowing only gaseous refrigerant to enter the compressor to prevent liquid slugging. Liquid refrigerant evaporates slowly in the cylinder before entering the compressor. Since there will be residual refrigerant oil in the system, an oil return hole is provided in the liquid separator, and the refrigerant oil will also return to the compressor in the liquid separator. With the protection of the liquid separator, the compressor's lifespan will be longer, and the system operation will be more stable. Safe working pressure -30KG/cm2 (special specifications can be customized).

Belongs to:

Gas-liquid separator


Product Description

  In an air conditioning system, before the refrigerant returns to the compressor, it must be ensured that the refrigerant is completely vaporized. Therefore, gas and liquid must be separated before entering the compressor, allowing only gaseous refrigerant to enter the compressor to prevent liquid slugging. Liquid refrigerant evaporates slowly in the cylinder and only enters the compressor after evaporation. Since there will be residual refrigerant oil in the system, an oil return hole is provided in the liquid separator, and the refrigerant oil will also return to the compressor in the liquid separator. With the protection of the liquid separator, the compressor's lifespan will be longer, and the system operation will be more stable. Safe working pressure -30KG/cm2 (special specifications can be customized). 
  Technical Parameters

Product Number

Specifications (inches)

Diameter A

Barrel Length B

Inlet/Outlet Length C

RA-204

1/2"

101.60

215.00

35.00

RA-205S

5/8"

215.00

35.00

RA-205

5/8"

275.00

35.00

RA-206

3/4"

140.00

260.00

40.00

RA-207S

7/8"

260.00

40.00

RA-207

7/8"

320.00

40.00

RA-211

11/8"

165.00

400.00

45.00

RA-213

13/8"

530.00

50.00

RA-215

15/8"

580.00

50.00

RA-221

21/8"

216.00

600.00

60.00

FA-221

21/8"

273.00

500.00

65.00

FA-225

25/8"

273.00

620.00

70.00

FA-231

31/8"

325.00

644.00

75.00

Keyword:

Refrigeration equipment

Compressor

Refrigeration fittings

Cooperation Intention Form


Leave your phone number, and we will contact you as soon as possible.

Submit

More Products


Safety SCW Series Horizontal Liquid Receiver

The inlet and outlet of SCW series horizontal liquid receiver are assembled with global valves.All the models are designed with 1/4”-18NPT safety valve connection. The designed pressure: 3.0MPa; Applicable refrigerants models:R134a, R22, R407C, R404A, R507A。

Safety SYQ Series Oil Seperator

SYQ series oil separator features a centrifugal separation. It can achieve high efficiency of oil separation with minimal pressure drop.SYQ series oil separator is designed for the parallel compressor units which installs electronic oil level regulator.it canstorage the separated oil in the bottom of the reservoir and send the oil which rely on the pressure differential between oil separator and compressor crankcase to each compressor crankcase by electronic oil level controller. There was no float ball valve .New upgraded product with 3/8”-18NPT oil charging port.Convenient for lubricant oil charging

Safety SYM Series Seperator

SYM series oil separator is mainly used for piston compressor and piston parallel compressor unit. SYM series oil separator features a centrifugal separation.It can achieve high efficiency of oil separation with minimal pressure drop Helical guide plate. It can keep high oil separation efficiency while the parallel compressor unit in load shedding or load.The gaseous refrigerants with suspended oil particles from the compressor and enters into the oil separator, the refrigerants with suspended oil particles contact the Helical guide plate , and rotate along the guide plate. Under the action of centrifugal force, the oil particles is separated into the edge of the Helical guide plate and on the vessel internal wall of the oil separator, where the isolated oil particles gather into larger oil droplets and flow into the oil collection area at the bottom of the oil separator. Designed pressure: 3.0MPa; Applicable refrigerants Models:R134a, R22, R407C, R404A, R507A.

Safety SYG Series Oil Seperator

SYG series oil separator primary used for Piston compressors,Piston parallel compressor units and the secondary oil separation of the spiral machines. SYG series oil separator features a centrifugal separation that can achieve high efficiency of oil separation with minimal pressure drop. The helical guide platecan keep high oil separation efficiency while the parallel compressor unit in load shedding or load change. There was installed a mist eliminator with stainless steel wires inside the oil separator, thus forming a barrier that captures the misty oil, making the oil flocculate,causing them toimpact each other, gather, and adsorb onto the mist eliminator to become oil droplets, finally reach the oil collection area of the separator by gravity. In this area, there was a flange that can separate the impurities of the oil droplets, also there was a permanent magnet which means it can absorb the iron debris. Designed pressure:3.0MPa;


Copyright Guangzhou Guangxue Refrigeration Equipment Co., Ltd All Rights Reserved.  Website:www.300.cn guangzhou.300.cn | Privacy PolicySEO

Business License