  • 微信图片_20250111113313.jpg
  • 微信图片_20250111113258.jpg

Piston series compressor

BITZER has always focused on improving compressor efficiency and launched the ECOLINE series of compressors specifically optimized for R134a several years ago. The R134a refrigerant has high performance in medium and high-temperature heat pump applications, including very high efficiency, lower pressure (reducing leakage rate), and the lowest GWP among all non-flammable HFC refrigerants.

Belongs to:

Piston series compressor


Product Description

  Product Introduction 
  International concern regarding the environmental impact of refrigeration systems is rapidly increasing, leading to reflection on refrigerants. The lower the energy consumption of a refrigeration system, the smaller its environmental impact and the lower its total lifecycle cost. Numerous regulations and standards have been or are being implemented in various regions of the world (such as the EU), all of which impose minimum energy efficiency requirements on refrigeration systems. 
  BITZER has always focused on improving compressor efficiency and launched the ECOLINE series of compressors specifically optimized for R134a several years ago. The R134a refrigerant offers high performance in medium- and high-temperature heat pump applications, including very high efficiency, low pressure (reducing leakage rates), and the lowest GWP among all non-flammable HFC refrigerants. 
  This gives the new BITZER ECOLINE compressor series a higher overall efficiency ratio. BITZER ECOLINE compressors can operate at lower condensing temperatures. Studies for the supermarket sector show that cascade refrigeration systems consisting of R134a and CO2 compressors (products optimized for total lifecycle cost and TEWI) offer particularly high ecological and economic efficiency and very low energy consumption. 
  The BITZER ECOLINE series now has more product models and expanded versatility. ECOLINE compressors can use a variety of common refrigerants, and their application range with these refrigerants has also been expanded compared to previous series. 
  The refrigerants that ECOLINE can now use include: R134a, R404A, R407A, R407C, R407F, F507, and R22. 
  The design of this series of compressors also considers the possibility of using low-GWP HFO or HFO family refrigerants. The COP of BITZER ECOLINE series compressors is up to 12% higher than previous products. 
  The improvement in product efficiency is achieved through further optimization of the compressor valve plate design, reduction of internal compressor losses, reduction of compressor exhaust pulsation, and the use of high-efficiency motors. 
  This series of compressors can also be used with inverters, with a frequency range of 30Hz to 70Hz for the CE3 series to the BE6 series, which can operate at variable frequencies between 25Hz and 70Hz. Therefore, the compressor's cooling capacity can be precisely matched to the system load. 
  Compressors specifically for R134a (No. 3 motor series) can be operated at up to 70Hz using a standard motor (400V/3/50Hz). 
  Product Features 
  New valve group design; 
  New cylinder head design for lower exhaust pulsation; 
  Optimized internal flow paths, reducing pressure losses; 
  New piston and connecting rod design; 
  High-efficiency motor. 
  Technical Parameters

Compressor 
Model Number

Motor 
Type

1450 rpm 
Displacement 
3/h

Number of Cylinders

Lubricating Oil 
Charging Quantity 
dm³

Weight 
kg

Discharge Pipe (DL) 
mm pouce

Suction Pipe (SL) 
mm pouce

Adjustable Range 
%①

Motor 
Connection Type 
Volt②

Maximum 
Operating Current 
Amp.③

Maximum 
Power Consumption 
kw③

70Hz with Inverter 
Operating Current 
Amp.⑤

2KES-05(Y)

1

4.06

2

1.0

43

12 1/2

16 5/8

-

△/Y 
220..240△/ 
380..420Y/3/50 
265..290△/ 
440..480Y/3/60

4.9/2.8

1.5

 

2JES-07(Y)

1

5.21

2

1.0

43

12 1/2

16 5/8

6.4/3.7

1.9

 

2HES-1M)

2

6.51

2

1.0

44

12 1/2

16 5/8

6.7/3.8

2.0

 

2HES-2(Y)

1

6.51

2

1.0

45

12 1/2

16 5/8

7.8/4.5

2.4

 

2GES-2(Y)

1

7.58

2

1.0

45

12 1/2

16 5/8

8.7/5.0

2.7

 

2FES-2(Y) 
2FES-3(Y)

2
1

9.54

2

1.0

45
47

12 1/2

16 5/8

9.2/5.3 
10.7/6.1

2.9
3.4

 

2EES-2(Y) 
2EES-3(Y)

2
1

11.4

2

1.5

68
71

16 5/8

22 7/8

10,4/6,0 
13/7/7/5

3.3
3,8

 

2DES-2(Y) 
2DES-3(Y)

2
1

13,4

2

1.5

68
71

16 5/8

22 7/8

13,4/7,5 
15,0/8,6

4,0 
4.6

 

2CES-3(Y) 
2CES-4(Y)

2
1

16,2

2

1.5

70
70

16 5/8

22 7/8

15,8/9,1 
17,4/10,0

5.0
5,6

 

4FES-3(Y) 
4FES-5(Y)

2
1

18,1

4

20

82
86

16 5/8

22 7/8

50

16,5/9,5 
18,8/10,8

5,3 
5,8

 

4EES-4(Y) 
4EES-6(Y)

2
1

22,7

4

2.0

84
86

16 5/8

28 11/8

21,2/12,2 
23,7/13,6

6.9
7,6

 

4DES-5(Y) 
4DES-7(Y)

2
1

26.8

4

20

86
89

22 7/8

28 11/8

25,2/14,5 
28,7/16,5

8,1 
8,9

 

4CES-6(Y) 
4CES-9(Y)

2
1

32,5

4

20

91
91

22 7/8

28 11/8

30,8/17,7 
35,1/20,2

9.7
11,3

 

4VES-6Y
4VES-7(Y) 
4VES-10(Y)

3
2
1

34,7

4

2.6

129
129
139

22 7/8

28 11/8

50

PW④ 
380..420YY/3/50 
440..480YY/3/60

10.0
16.6
19.9

6
11
12

14,8 
— 

4TES-8Y
4TES-9(Y) 
4TES-12(Y)

3
2
1

41,3

4

2.6

134
134
141

28 11/8

35 13/8

12.1
19.9
25.1

7
13
14

17.6
— 

4PES-10Y
4PES-12(Y) 
4PES-15(Y)

3
2
1

48,5

4

2.6

139
139
147

28 11/8

35 13/8 
35 13/8 
42 15/8

13.6
22.7
28.2

8
14
16

21,0 
— 

4NES-12Y
4NES-14(Y) 
4NES-20(Y)

3
2
1

56.2

4

2.6

141
141
150

28 11/8

35 13/8 
35 13/8 
42 15/8

15.9
26.6
33,2

9
17
19

25,2 
— 

4JE-13Y
4JE-15(Y) 
4JE-22(Y)

3
2
1

63.5

4

4.0

179
190
190

28 11/8

42 15/8

19.8
30,8 
37.2

11
19
21

28,6 
— 

4HE-15Y
4HE-18(Y) 
4HE-25(Y)

3
2
1

73.7

4

4.0

183
190
194

28 11/8

42 15/8 
42 15/8 
54 21/8

22.5
36.7
44.0

13
22
25

32,5 
— 

4GE-20Y
4GE-23(Y) 
4GE-30(Y)

3
2
1

84.6

4

4.5

192
192
206

28 11/8

54 21/8

25.9
43.9
51.2

16
27
28

38.1
— 

4FE-25Y
4FE-28(Y) 
4FE-35(Y)

3
2
1

101,8

4

4.5

196
207
207

28 11/8

54 21/8

32,1 
52.8
62,1

19
31
35

46,6 
— 

6JE-22Y
6JE-25(Y) 
6JE-33(Y)

3
2
1

95,3

6

4,75

213
228
231

35 13/8

54 21/8

66
altern. 
33

380..420YY/3/50
440..480YY/3/60 
PW④

28,5 
46.4
53,2

16
27
30

42,4 

6HE-25Y
6HE-28(Y) 
6HE-35(Y)

3
2
1

110,5

6

4,75

224
228
235

35 13/8

54 21/8

32.9
53.2
64.4

19
33
36

48,2

6GE-30Y
6GE-34(Y) 
6GE-40(Y)

3
2
1

126,8

6

4,75

228
228
238

35 13/8

54 21/8

40,0 
65.5
73.9

23
40
42

58,4 

6FE-40Y
6FE-44(Y) 
6FE-50(Y)

3
2
1

151,6

6

4,75

238
241
241

42 15/8

54 21/8

380..400YY/3/50
440.460YY/3/60

51,1 
83.2
96,2

27
46
51

75,5 
— 
— 

8GE-50(Y) 
8GE-60(Y)

2
1

185

8

5.0

342
350

42 15/8

76 31/8

75
altern. 
50

PW④ 
380..420△△/3/50 
440..480△△/3/60

92,0 
113.0

51
63

— 

8FE-60(Y) 
8FE-70(Y)

2
1

221

8

5.0

361
374

54 21/8

76 31/8

113,0 
139.0

63
78

— 


  Notes 
  ① Adjustable device (optional): 220V .. 240V / 1/50/60Hz 
  ② The allowable deviation is 10% of the rated value. Please consult Bitzer for other electrical products. 
  ③ Data are parameters under 400V/3/50Hz conditions. When selecting contactors, cables, and fuses, please refer to the compressor's maximum operating current or maximum operating power. Also see ⑤. 
  Please use a thermal relay to limit the maximum operating current. For contactors, please select AC3 products. Please use a thermal relay to protect the compressor's maximum operating current. 
  ④ PW: The motor is a split-winding start Y/YY 
    ● 4VES-6Y … 6FE-50Y The split-winding capacity ratio is 50%/50% 
    ● Select the motor contactor according to 60% of the maximum operating current. Motor 3 variable frequency operation: Select the contactor according to the maximum operating current at 70Hz. 
    ● 8GE-50(Y) .. 8FE-70(Y) △/△△ split winding 60%/40% 
     Select the first coil contactor according to 70% of the maximum operating current 
     Select the second coil contactor according to 50% of the maximum operating current 
    ● For split-winding motors, please refer to 60% of the motor's maximum operating current when selecting the contactor. 
    ● Y / Ɣ motors, please consult Bitzer. 
  ⑤ When the compressor is used with a variable frequency drive 
   —Compressors equipped with motor No. 3 (R134a dedicated compressors) can use a 400V/3/50Hz standard motor increased to 70Hz under 400V/3/50Hz power supply conditions. 
   Products equipped with motors No. 1 and 2 require special motors if they need to be used above 50Hz in the entire application range. 
   Please consult Bitzer for variable frequency compressor use.

Keyword:

Refrigeration equipment

Compressor

Refrigeration fittings

Cooperation Intention Form


Leave your phone number, and we will contact you as soon as possible.

Submit

More Products


Safety SCW Series Horizontal Liquid Receiver

The inlet and outlet of SCW series horizontal liquid receiver are assembled with global valves.All the models are designed with 1/4”-18NPT safety valve connection. The designed pressure: 3.0MPa; Applicable refrigerants models:R134a, R22, R407C, R404A, R507A。

Safety SYQ Series Oil Seperator

SYQ series oil separator features a centrifugal separation. It can achieve high efficiency of oil separation with minimal pressure drop.SYQ series oil separator is designed for the parallel compressor units which installs electronic oil level regulator.it canstorage the separated oil in the bottom of the reservoir and send the oil which rely on the pressure differential between oil separator and compressor crankcase to each compressor crankcase by electronic oil level controller. There was no float ball valve .New upgraded product with 3/8”-18NPT oil charging port.Convenient for lubricant oil charging

Safety SYM Series Seperator

SYM series oil separator is mainly used for piston compressor and piston parallel compressor unit. SYM series oil separator features a centrifugal separation.It can achieve high efficiency of oil separation with minimal pressure drop Helical guide plate. It can keep high oil separation efficiency while the parallel compressor unit in load shedding or load.The gaseous refrigerants with suspended oil particles from the compressor and enters into the oil separator, the refrigerants with suspended oil particles contact the Helical guide plate , and rotate along the guide plate. Under the action of centrifugal force, the oil particles is separated into the edge of the Helical guide plate and on the vessel internal wall of the oil separator, where the isolated oil particles gather into larger oil droplets and flow into the oil collection area at the bottom of the oil separator. Designed pressure: 3.0MPa; Applicable refrigerants Models:R134a, R22, R407C, R404A, R507A.

Safety SYG Series Oil Seperator

SYG series oil separator primary used for Piston compressors,Piston parallel compressor units and the secondary oil separation of the spiral machines. SYG series oil separator features a centrifugal separation that can achieve high efficiency of oil separation with minimal pressure drop. The helical guide platecan keep high oil separation efficiency while the parallel compressor unit in load shedding or load change. There was installed a mist eliminator with stainless steel wires inside the oil separator, thus forming a barrier that captures the misty oil, making the oil flocculate,causing them toimpact each other, gather, and adsorb onto the mist eliminator to become oil droplets, finally reach the oil collection area of the separator by gravity. In this area, there was a flange that can separate the impurities of the oil droplets, also there was a permanent magnet which means it can absorb the iron debris. Designed pressure:3.0MPa;


Copyright Guangzhou Guangxue Refrigeration Equipment Co., Ltd All Rights Reserved.  Website:www.300.cn guangzhou.300.cn | Privacy PolicySEO

Business License