  • 吸气过滤芯 (1)(1775111742954).png
  • 微信图片_20260324164908_108_244.jpg
  • 微信图片_20260324164911_109_244.jpg
  • 微信图片_20260324164912_110_244.jpg
  • 微信图片_20260324164914_111_244.jpg
  • 微信图片_20260324164916_112_244.jpg

Safety SGL2 series fillters

When the SGL2 series filters are used as liquid supply line filter, installing solid dry filter cartridges can filter impurities, absorb moisture and acidic substances in the system; When used as suction line filter, we recommend to remove the two metal filter in order to reduce pressure drop. Using SFE series fiber pleated and SFE-W stainless steel cartridge shall effectively filter out the impurities in the system and avoid the dirts entering the compressor to extend the service life of the compressor.

Belongs to:

SGL2 series filters


Product Description

        When the SGL2 series filters are used as liquid supply line filter, installing solid dry filter cartridges can filter impurities, absorb moisture and acidic substances in the system; When used as suction line filter, we recommend to remove the two metal filter in order to reduce pressure drop. Using SFE series fiber pleated and SFE-W stainless steel cartridge shall effectively filter out the impurities in the system and avoid the dirts entering the compressor to extend the service life of the compressor.
Highlights:
  • Anti-Corrosion protection epoxy powder

 

  • coating and carbon steel housing
  • Carbon steel inlet and outlet connector,
  • copper pipe shall be inserted
  • Simple internal plated steel parts
  • Easy installation
  • Built-in two metal mesh screens
  • Access port for measuring pressure drop
  • and charging
  • Strong and long service time
  • Replaceable filter element
  • Two types filter elements shall be used
  • for Suction line filter
  • Efficiency to filter impurities, moisture
  • and acidic substances
  • Provide better protection for Compressor
  • Designed pressure3.0MPa
  • Applicable refrigerants Models
  • R134a, R22, R407C, R404A, R507A

Model

Core-Quantity
(Piece)

ODS Coon. copper tube(internal iameter)

(inch)

Tube (external) diameter
(mm)

L
(mm)

L1
(mm)

H
(mm)

Volume
(L)

SGL2-116

1

5/8"

20

239

169

97

1.7

SGL2-122

1

7/8"

28

239

165

97

1.7

SGL2-128

1

1-1/8"

34

239

162

97

1.7

SGL2-135

1

1-3/8"

40

244

164

102

1.7

SGL2-142

1

1-5/8"

50

246

163

107

1.7

SGL2-154

1

2-1/8"

60

244

154

107

1.7

SGL2-222

2

7/8"

28

379

305

97

2.9

SGL2-228

2

1-1/8"

34

379

302

97

2.9

SGL2-235

2

1-3/8"

40

384

304

102

2.9

SGL2-328

3

1-1/8"

34

534

457

112

4.2

SGL2-335

3

1-3/8"

40

543

463

122

4.2

Keyword:

Refrigeration equipment

Compressor

Refrigeration fittings

Cooperation Intention Form


Leave your phone number, and we will contact you as soon as possible.

Submit

More Products


Safety SQM Series Gas-Liquid Separators

The sunction accumulator is an important part of the refrigeration system. The most important function of the separator is to separate the gaseous and liquid refrigerants for preventing “liquid slugging” of compressor (liquid refrigerants flows into the compressor). Reasons to cause “ Liquid Slugging”: Improperly installed piping(inlet-outlet) Insufficient capacity of evaporator Expansion valve selection error Refrigerants overcharging Over Frosting of evaporator Evaporator fan not running Insufficient heat insulating and low environment temperatures of suction pipes Recommendations to install: Compressor parallel Two-stages compression refrigeration/compound refrigerants compressor Flooded evaporation system Defrosting system by superheated vapour Heat-pump system Over-heat degree lower than 7K system Attentions to choose: Determine the relationship between the volume of the sunction accumulator and the amount of the system refrigerants charging. Basically, the sunction accumulator can store 30 percent to 50 percent refrigerants of the system. The flow velocity of U-shaped vertical raising pipe not lower than 7.5 m/s in order to favorable oil return effect,and not greater than 12 m/s, especially low evaporating temperature system. Capacity controlled refrigerating units should be considered the velocity of the suction pipe;for the parallel compressor unit, the multiple suction pipes of the separator should be the best choice. (Multiple suction pipes separator is installed behind the suction pipe, one suction pipe for one compressor to make sure every compressor can get the same velocity). Vertical installation Install close to the suction inlet of the compressor Designed pressure: 3.0MPa Applicable refrigerants models: R134a, R22, R407c, R404A, R507A

Safety SGS serier fillters

When the SGS series filters are used as liquid supply line filter, installing solid dry filter cartridges can filter impurities, absorb moisture and acidic substances in the system; When used as suction line filter, we recommend to remove the two metal filter in order to reduce pressure drop. Using SFE series fiber pleated and SFE-W stainless steel cartridge shall effectively filter out the impurities in the system and avoid the dirts entering the compressor to extend the service life of the compressor.

Safety SGL2 series fillters

When the SGL2 series filters are used as liquid supply line filter, installing solid dry filter cartridges can filter impurities, absorb moisture and acidic substances in the system; When used as suction line filter, we recommend to remove the two metal filter in order to reduce pressure drop. Using SFE series fiber pleated and SFE-W stainless steel cartridge shall effectively filter out the impurities in the system and avoid the dirts entering the compressor to extend the service life of the compressor.

Bitzer Semi-hermetic Screw Compressor

   The HS series is a range of semi-hermetic screw compressors with built-in motors, suitable for large-scale commercial refrigeration and process cooling. They can be used in both onshore and offshore systems. The HS series is known for its proven robustness, excellent energy efficiency at both full and part load, and compatibility with a wide variety of synthetic refrigerants. Multiple RefrigerantsHFC, HFC blends, HCFC, Non-flammable A1HFO blends, Non-flammable A1HFO blends, Flammable A2LHFO, Flammable A2L.Product Range 4 Series: HS.53, HS.64, HS.74, and HS.8513 Models: 84 to 535 m³/h @ 50 Hz.ApplicationsMedium and low temperature cold storageAir coolers / FreezersProcess and air conditioning chillersIce makingHeat recoveryIndustrial SectorsFood and beverage industryChemical and pharmaceutical industryMarine and offshore industry.


Copyright Guangzhou Guangxue Refrigeration Equipment Co., Ltd All Rights Reserved.  Website:www.300.cn guangzhou.300.cn | Privacy PolicySEO

Business License