Safety SQM Series Gas-Liquid Separators
The sunction accumulator is an important part of the refrigeration system. The most important function of the separator is to separate the gaseous and liquid refrigerants for preventing “liquid slugging” of compressor (liquid refrigerants flows into the compressor). Reasons to cause “ Liquid Slugging”: Improperly installed piping(inlet-outlet) Insufficient capacity of evaporator Expansion valve selection error Refrigerants overcharging Over Frosting of evaporator Evaporator fan not running Insufficient heat insulating and low environment temperatures of suction pipes Recommendations to install: Compressor parallel Two-stages compression refrigeration/compound refrigerants compressor Flooded evaporation system Defrosting system by superheated vapour Heat-pump system Over-heat degree lower than 7K system Attentions to choose: Determine the relationship between the volume of the sunction accumulator and the amount of the system refrigerants charging. Basically, the sunction accumulator can store 30 percent to 50 percent refrigerants of the system. The flow velocity of U-shaped vertical raising pipe not lower than 7.5 m/s in order to favorable oil return effect,and not greater than 12 m/s, especially low evaporating temperature system. Capacity controlled refrigerating units should be considered the velocity of the suction pipe;for the parallel compressor unit, the multiple suction pipes of the separator should be the best choice. (Multiple suction pipes separator is installed behind the suction pipe, one suction pipe for one compressor to make sure every compressor can get the same velocity). Vertical installation Install close to the suction inlet of the compressor Designed pressure: 3.0MPa Applicable refrigerants models: R134a, R22, R407c, R404A, R507A
Belongs to:
SQM Series Gas-Liquid Separators
Product Description
- Improperly installed piping(inlet-outlet)
- Insufficient capacity of evaporator
- Expansion valve selection error
- Refrigerants overcharging
- Over Frosting of evaporator
- Evaporator fan not running
- Insufficient heat insulating and low environment
- temperatures of suction pipes
- Compressor parallel
- Two-stages compression refrigeration/compound
- refrigerants compressor
- Flooded evaporation system
- Defrosting system by superheated vapour
- Heat-pump system
- Over-heat degree lower than 7K system
- Determine the relationship between the volume of the sunction accumulator and the amount of the system refrigerants charging. Basically, the sunction accumulator can store 30 percent to 50 percent refrigerants of the system.
- The flow velocity of U-shaped vertical raising pipe not lower than 7.5 m/s in order to favorable oil return effect,and not greater than 12 m/s, especially low evaporating temperature system.
- Capacity controlled refrigerating units should be considered the velocity of the suction pipe;for the parallel compressor unit, the multiple suction pipes of the separator should be the best choice. (Multiple suction pipes separator is installed behind the suction pipe, one suction pipe for one compressor to make sure every compressor can get the same velocity).
- Vertical installation
- Install close to the suction inlet of the compressor
- Designed pressure: 3.0MPa
- Applicable refrigerants models:
- R134a, R22, R407c, R404A, R507A

Model | Conn. Size | Tube external diameter (mm) | φD | H | A | φG | Y | φZ | Volume | Fig. |
|---|---|---|---|---|---|---|---|---|---|---|
SQM-16 | 1/2" | 16 | 114 | 275 | 54 | 140 | 86 | 9 | 2.1 | a |
SQM-20 | 5/8" | 20 | 114 | 345 | 54 | 140 | 86 | 9 | 2.7 | a |
SQM-25 | 3/4" | 25 | 140 | 340 | 80 | 160 | 96 | 9 | 4 | a |
SQM-28 | 7/8" | 28 | 140 | 420 | 80 | 160 | 96 | 9 | 5 | a |
SQM-34 | 1-1/8" | 34 | 165 | 473 | 80 | 190 | 120 | 9 | 8 | a |
SQM-42 | 1-3/8" | 42 | 165 | 473 | 83 | 190 | 120 | 9 | 8 | a |
SQM-50 | 1-5/8" | 50 | 219 | 446 | 106 | 250 | 155 | 13 | 13 | a |
SQM-60 | 2-1/8" | 60 | 273 | 496 | 127 | 295 | 193 | 13 | 21 | b |
SQM-76 | 2-5/8" | 76 | 273 | 556 | 150 | 295 | 193 | 13 | 24 | b |
Keyword:
Refrigeration equipment
Compressor
Refrigeration fittings
Cooperation Intention Form
Leave your phone number, and we will contact you as soon as possible.
More Products
Safety SQM Series Gas-Liquid Separators
The sunction accumulator is an important part of the refrigeration system. The most important function of the separator is to separate the gaseous and liquid refrigerants for preventing “liquid slugging” of compressor (liquid refrigerants flows into the compressor). Reasons to cause “ Liquid Slugging”: Improperly installed piping(inlet-outlet) Insufficient capacity of evaporator Expansion valve selection error Refrigerants overcharging Over Frosting of evaporator Evaporator fan not running Insufficient heat insulating and low environment temperatures of suction pipes Recommendations to install: Compressor parallel Two-stages compression refrigeration/compound refrigerants compressor Flooded evaporation system Defrosting system by superheated vapour Heat-pump system Over-heat degree lower than 7K system Attentions to choose: Determine the relationship between the volume of the sunction accumulator and the amount of the system refrigerants charging. Basically, the sunction accumulator can store 30 percent to 50 percent refrigerants of the system. The flow velocity of U-shaped vertical raising pipe not lower than 7.5 m/s in order to favorable oil return effect,and not greater than 12 m/s, especially low evaporating temperature system. Capacity controlled refrigerating units should be considered the velocity of the suction pipe;for the parallel compressor unit, the multiple suction pipes of the separator should be the best choice. (Multiple suction pipes separator is installed behind the suction pipe, one suction pipe for one compressor to make sure every compressor can get the same velocity). Vertical installation Install close to the suction inlet of the compressor Designed pressure: 3.0MPa Applicable refrigerants models: R134a, R22, R407c, R404A, R507A
When the SGS series filters are used as liquid supply line filter, installing solid dry filter cartridges can filter impurities, absorb moisture and acidic substances in the system; When used as suction line filter, we recommend to remove the two metal filter in order to reduce pressure drop. Using SFE series fiber pleated and SFE-W stainless steel cartridge shall effectively filter out the impurities in the system and avoid the dirts entering the compressor to extend the service life of the compressor.
When the SGL2 series filters are used as liquid supply line filter, installing solid dry filter cartridges can filter impurities, absorb moisture and acidic substances in the system; When used as suction line filter, we recommend to remove the two metal filter in order to reduce pressure drop. Using SFE series fiber pleated and SFE-W stainless steel cartridge shall effectively filter out the impurities in the system and avoid the dirts entering the compressor to extend the service life of the compressor.
Bitzer Semi-hermetic Screw Compressor
The HS series is a range of semi-hermetic screw compressors with built-in motors, suitable for large-scale commercial refrigeration and process cooling. They can be used in both onshore and offshore systems. The HS series is known for its proven robustness, excellent energy efficiency at both full and part load, and compatibility with a wide variety of synthetic refrigerants. Multiple RefrigerantsHFC, HFC blends, HCFC, Non-flammable A1HFO blends, Non-flammable A1HFO blends, Flammable A2LHFO, Flammable A2L.Product Range 4 Series: HS.53, HS.64, HS.74, and HS.8513 Models: 84 to 535 m³/h @ 50 Hz.ApplicationsMedium and low temperature cold storageAir coolers / FreezersProcess and air conditioning chillersIce makingHeat recoveryIndustrial SectorsFood and beverage industryChemical and pharmaceutical industryMarine and offshore industry.